• TTi高精度直流电源QL355QL355PQL355TP

    详细信息

     品牌:TTI  型号:QL355QL355PQL355TP  加工定制:否  
     重量:8 ㎏   
     英国TTi QL系列高精度直流电源 QL355 QL355P QL355TP
    真正的线性调节精度控制
    QL系列II是*新的和*高的性能的线性稳压电源系列从TTI
    单输出和三组输出模型是可用的。每个型号可以选择数字远程控制接口。
    每个主要的输出提供了超过100W的功率,双输出功能提供更高的电流在低电压。
    新的功能包括一个增强的辅助输出可变的电压和电流的T型号,以及LXI的标准网络接口的所有P型号。
         产品特点:
    • 先进的直流电源,单组或三组输出
    • 高精度,低噪音,良好的动力学
    • 数字旋转控制先进的用户界面
    • 增加灵活性的多电压/电流范围
    • 电源设置多个非易失性存储器
    • 可切换的遥感提供了完美的负载调整
    • 综合保护包括过压保护和OCP旅行
    • 紧凑的台式足迹;机架安装模块宽度
    • 辅助输出完全变1.00V6.00v 3A
    • 可选择的电压和电流测量(带T型号)
    • 总线可编程通过USBRS232GPIBLAN(带P型号)
    • 局域网接口CLXI兼容
    • 双电源后方Sense端子(带P型号)
         产品型号/规格:
    • QL355, QL355P, QL355T, QL355TP
      Max. Output Power: 105 watts
      Output Ranges: Range 1 - 0 to 35V, 0 to 3A
                              Range 2 - 0 to 15V, 0 to 5A
                              Range 3 - 0 to 35V, 0 to 500.0mA
    • QL564, QL564P, QL564T, QL564TP
      Max. Output Power: 112 watts
      Output Ranges: Range 1 - 0 to 56V, 0 to 2A
                              Range 2 - 0 to 25V, 0 to 4A
                              Range 3 - 0 to 56V, 0 to 500.0mA
      All Models
      Voltage Setting: By floating point numeric entry or rotary jog wheel; resolution 1mV.
      Current Setting: By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range.
      Setting Accuracy: Voltage - 0.03% +/-5mV. Current 0.2% +/-5mA/0.5mA
      Output Mode: Operation in constant voltage or constant current modes with automatic cross-over and mode indication.
      DC Output Switch: Sets output voltage and current levels to zero when Off.
       
      Output Terminals: 4mm safety binding post terminals on 19mm (0.75") spacing.
        Duplicated on rear terminal block (P versions only)
      Load Regulation: For any load change, at the output terminals, using remote sense.
         Voltage <0.01% + 2mV. Current <0.01% + 250uA; <0.01% +50uA on 500mA range.
         (Add typically 2.5mV for a 0.5V drop in the positive output lead.)
      Line Regulation: Voltage <0.01% + 2mV for 10% change.Current <0.01% + 250uA; <0.01%+ 50uA on 500mA range
      Ripple and Noise: Typically <0.35mV rms CV mode, and <0.2mA rms CI mode (<20uA rms on 500mA range)
      Common Mode Noise Current: <4uA rms at 20MHz bandwidth.
      Transient Response: <20usec to within 15mV of setting for 90% load change
      Temperature Coeff.: <(50ppm+0.5mV)/ oC (voltage), <(100ppm+1mA/0.1mA)/oC (current)
      Remote Sense: Eliminates up to 0.5V drop per lead. Remote sense operation selected from front panel and indicated
         by LED
      Sense Terminals: Recessed sprung sockets for direct insertion of wires
       
         Duplicated on rear terminal block (P versions only)
    OUTPUT PROTECTION
    Output Protection: Output will withstand forward voltages of up to 20V above rated output voltage. 
      Reverse protection by diode clamp for currents up to 3A.
    Fault Condition Trip: The output will be shut down if any of the four trip conditions listed below occur.
     
        (In addition to the output being set to Off, an isolated rear panel signal is also activated.)
      Over Voltage (OVP): Settable 1V to 40V (QL355) or 60V (QL564) in 0.1V steps
      Over Current (OCP): Settable 0.1A to 5.5A (QL355) or 4.5A (QL564) in 0.01A steps
      Over Temperature: Monitors internal temperature rise to protect against excess ambient temperature or blocked
       ventilation slots.
      Sense Error: Monitors the voltage between the remote sense terminals and output terminals to protect against
     
       mis-wiring.
    Trip Output Signal: Isolated open-collector output signal on rear panel.

    METERING
    Display Type: Dual digital displays per output using 14mm (0.56") high brightness LEDs. 
      5 digits for voltage, 4 digits for current. Update rate 4 per second. 
    Meter Function: 
      Voltage meter shows set voltage when in CV mode and measured voltage when in CI mode. 
      Current meter shows measured current when in CV mode and set current when in CI mode.
      Limits Display: With the dc output switch set to Off, both meters show the set values (i.e. the limits).
     
       With the output On, either the voltage meter or current meter will show a measured value (depending on the CV/CI 
       mode). Pressing the Limits button will provide a temporary display of the set values.
    Watts (VxA) Display: The voltage meter can be made to show the calculated product of voltage and current.
    Meter Resolution:
     
      Voltage: 1mV (CV mode) or 10mV (CI mode)
      Current: 1mA or 0.1mA depending on range
      Power: 0.01W or 0.001W depending on range
    Meter Accuracy:
     
      Voltage: 0.1% of reading +/-10 mV (CI mode)
      Current: 0.2% of reading +/- 0.005A or 0.5mA (CV mode)
      Power: 0.3% of reading +/- 0.05W or 0.005W

    SETTINGS MEMORIES
    Main Output(s): Up to 50 set-ups per output can be saved and recalled via the keyboard or remote interfaces.
    Parameters Stored: Range, Set volts, Set current, OVP, OCP.
    Recall system: Settings are previewed onto the displays before being actioned.
    Linked Mode: On triple output models when in Linked mode, a further set of 50 memories stores and recalls values
     
    for both outputs simultaneously.
    Auxiliary Output: Up to 10 voltage settings can be saved and recalled via the keyboard or remote interfaces.

    ALARM OUTPUT
    Isolated rear-panel open-collector output signal. User can select output to be activated for either OVP, OCP, Overtemperature or Sense miswiring, or for any of those four faults.
    LINK & COPY - Triple Output Models
    Each output can be controlled independently or can be linked. When linked, keyboard and jog wheel control operates on both outputs simultaneously.
    Linked mode can be used to create tracking outputs, or for convenient series or parallel operation of the two outputs.
    A Copy function is available which copies all of the settings for output 1 to output 2 (Range, Set volts, Set current, OVP, OCP).
    Linked mode can also be used to store the settings for both outputs to a group of common memory stores when simultaneous recall is required.
    (Note: Linked mode can be selected with differing voltage and current settings on the two outputs. However both outputs must be set to the same range.)

    AUXILIARY OUTPUT - Triple Output Models
    Output Voltage: 1.00 to 6.00V
    Output Current: >3.0 A maximum. LED indication of over-current.
    DC Output Switch: Sets output voltage level to zero when Off.
     
    Setting Accuracy: 0.5% +/-10mV
    Ripple and Noise: <2mV rms, 10mVp-p
    Load Regulation: < 1% for 90% load change.
    Line Regulation: < 0.1% for 10% line change.
    Meter Accuracy: Voltage 0.5% +/-10mV, Resolution 10mV
    Current 0.5% +/-10mA, Resolution 10mA
    Output Regulation: Switch-mode down converter.
    Output Protection: Output will withstand up to 16 V forward voltage. Diode clamped for
    reverse voltages and 1 Amps reverse current.
    Output Terminals: 4mm safety binding post terminals on 19mm (0.75") spacing.
    Duplicate screwless terminals at rear (P versions only)

    DIGITAL BUS INTERFACES (P suffix versions only)
    Full remote control and read-back using RS-232, USB, GPIB or LAN (compliant with LXI class C). All interfaces are at ground potential and opto-isolated from the output terminals.
    RS-232: Standard 9-pin D connector. Baud rate variable 600 to 19,200.
    USB: USB 2.0 connection (backwards compatible with USB 1.x). Operates as a virtual COM port.
    GPIB (IEEE-488): The interface conforms with IEEE-488.1 and IEEE-488.2.
    Ethernet (LAN): Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol for connection to Local Area Network or direct connection to a single PC.
    LXI Compliance: LAN interface is compliant with LXI class C. (LXI is the abbreviation for Lan eXtensions for Instrumentation). For more information visit:
     www.tti-test.com/go/lxi
    DIGITAL PROGRAMMING PERFORMANCE (P versions only)
    Voltage Setting - Main Output(s)
    Resolution/Accuracy: 1mV / +/- (0.03% +5mV)
    Current Setting - Main Output(s)
    Resolution/Accuracy: 0.1mA / +/- (0.2% +5mA) or 0.01mA / +/- (0.2% +0.5mA) on 500mA range
    Voltage Setting - Auxiliary Output (Triple Output Models)
    Resolution/Accuracy: 10mV / +/- (0.5% +10mV)
     
    Programming Speed
    Command Delay: Typically <25ms (this must be added to any of the figures below)
    Voltage Up Time: <10ms* to 1%
    Voltage Down Time: <40ms* to 1% (full load); <0.6s* to 1% (no load)
    * The up and down times vary with range and voltage step size. More information is contained in the operating manual which can be downloaded from our web site.

    DRIVER SOFTWARE SUPPLIED (P versions only)
    IVI Driver: An IVI driver for Windows is supplied. This provides support for common applications such as LabView*,
       LabWindows*, HPVEE* etc.
    USB Driver: An installation file is supplied which calls a standard Windows* USB driver.

    * LabView and LabWindows are trademarks of National Instruments. 
      HPVEE (now Agilent VEE) is a trademark of Agilent Technologies. 
    * USB interface is supported for Windows 2000, XP, Vista and Windows 7. Further versions will be
      supported as they are released.  Windows is a trademark of Microsoft.

    KEYBOARD & ROTARY CONTROL
    All functions, including the selection and set-up of the remote control interfaces, can be set from the keyboard. The rotary jog control can be used to adjust output voltage and current settings in a quasi-analogue mode.
    GENERAL SPECIFICATIONS
    Input
    AC Input: 230V AC or 115V AC +/- 10%, 50/60HzInstallation Category II.
    Input Power: Single - 250VA max., Triple - 500VA max.
    Temperature & Environmental
    Operating Range: +5oC to +40oC, 20% to 80% RH
    Storage Range: -40oC to + 70oC
    Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
    Cooling: Intelligent variable-speed fan. Over-temperature trip shuts down output if internal temperatures exceed
       predetermined thresholds.
     
    Safety & EMC
    Safety: Complies with EN61010-1
    EMC: Complies with EN61326
    Physical
    Size: Single - 140 x 160 (1/3 rack, 4U) x 290mm;  Triple - 280 x 160 (2/3 rack, 4U) x 290mm
      (size excludes feet, knobs and terminals).
    Weight: Single - 5.5kg (12lb), Triple - 10.5kg (23lb)

    OPTIONS
    Rack Mount
    RM410 19 inch 4U mount for up to three single output units or one triple plus one single. Blanking plates are supplied for unused sections.


    Accuracy specifications apply for the temperature range 18oC to 28oC after one hour warm-up.